Accelerate Pheno™ system
Accelerate Pheno™ system
Features
Fast – Accelerate PhenoTest™ BC kit
Average time to results:
- Identification in less than 90 minutes.
- Antibiotic susceptibility in about 7 hours
Fully Automated
- Entire process within 1 kit,
- 2 minutes to load & start Direct from sample
- No culturing for isolates
- No manual McFarland prep
Actionable Results
- MIC-based susceptibilities
- SIR interpretations
- CLSI/EUCAST breakpoints
- Expert & Custom Rules
- Access anywhere software
Kit
One simple kit, over 1000 results
Automated Sample Preparation
Sample cleanup, dilution, cell capture and positioning. All hands-free.
Sample cleanup
Designed to accelerate your susceptibility testing, the system automatically cleans each sample using gel electrofiltration. Combined with additional system capability for polymicrobial infections, this process cuts hours of wait for you by reducing the need to grow cultures overnight before testing.#
Diluting dynamically, automatically
A technician’s time is precious and for susceptibility testing, so is an accurate inoculum. Solving this time and accuracy problem, the Accelerate Pheno™ system determines sample concentration and dilutes dynamically right on the cassette.
No McFarland standards needed.
Cell capture and positioning
Living cells move around making precise visual measurements difficult. To solve this, the system captures microbial cells onto the cassette surface, positioning them for analysis.
Identification
Detect, Identify, Quantify
One system for your identification and susceptibility results. Fast and fully automated fluorescence in-situ hybridization drives pathogen detection, species identification, and quantitation.
Susceptibility
Which antibiotic. How much. How often.
Move your patients from empiric to optimal therapy faster using MIC results from the Accelerate Pheno™ system.
Powered by Morphokinetic Cellular Analysis (MCA), the system is the first to track phenotypic features including the size, shape, and division rate of individual live cells growing into micro-colonies while being challenged by antibiotics.
Software
Diagnostics can be complex. The software shouldn’t be.
Easy to use and accessible from most browsers, the software was designed for microbiologists to use both inside and outside of the lab. Create a set of rules that fits your lab with condition-based notes and follow-up actions. Have the flexibility to manage testing in the lab and securely review reports from your office or home.
- Dashboard
- Lab Report
- Custom Report
- Custom Rules
- Breakpoints
- Mobile
Benefits:
- Review results before publishing
- Use your lab abbreviations
- Select your sample identifiers
Technical Specifciations
- Web-based local application supporting most browsers compatible with HTML5 and CSS3, validated on Microsoft Internet Explorer 11.
- Includes specialized Graphical Processing Unit (GPU) and associated software required for analysis of images acquired with the Accelerate ID/AST System.
- Capacitive touch or Keyboard and Mouse.
- Susceptible
- Intermediate
- Resistant
- Nonsusceptible
- Positive for resistance phenotype
- Negative for resistance phenotype
- EUCAST
- CLSI
- Identification
- MIC results and interpretation for each organism/drug combination
- Expert Rules and any applicable comments
- 1 sample per module, up to 4 samples in parallel per system.
- Each test may run from a minimum of 1 hour to a maximum of 8 hours.
- Nominal 120 Volts AC 50/60 Hz 12 Amps
- 6 ft. long cable with standard NEMA 5-15 plug
- Input range – 88-139 Volts AC
Analysis system:
- Nominal 100 Volts AC 50/60 Hz 12 Amps
- Nominal 115 Volts AC 50/60 Hz 12 Amps
- Nominal 200-240 Volts 50/60 Hz 10 Amps
- Web-based local application supporting most browsers compatible with HTML5 and CSS3, validated on Microsoft Internet Explorer 11.
- Includes specialized Graphical Processing Unit (GPU) and associated software required for analysis of images acquired with the Accelerate ID/AST System.
- Capacitive touch or Keyboard and Mouse
- Susceptible
- Intermediate
- Resistant
- Nonsusceptible
- Positive for resistance phenotype
- Negative for resistance phenotype
- EUCAST
- CLSI
- Identification
- MIC results and interpretation for each organism/drug combination
- Expert Rules and any applicable comments
- 1 sample per module, up to 4 samples in parallel per system.
- Each test may run from a minimum of 1 hour to a maximum of 8 hours.
- Nominal 120 Volts AC 50/60 Hz 12 Amps
- 6 ft. long cable with standard NEMA 5-15 plug
- Input range – 88-139 Volts AC
Analysis system:
- Nominal 100 Volts AC 50/60 Hz 12 Amps
- Nominal 115 Volts AC 50/60 Hz 12 Amps
- Nominal 200-240 Volts 50/60 Hz 10 Amps
Physical Specifications
- Modules (1 to 8)
- Control PC
- Analysis PC
- UPS
- Touchscreen monitor
- Height: 16.8″ (42.6 cm)
- Width: 13.1″ (33.4 cm)
- Depth: 19.6″ (49.7cm)
- Weight: 70 lbs (32kg)
- 1 module system – 3 ft. (1 m) bench space
- 4 module system – 7 ft. (2.33 m) bench space
- Bench level within 2°
- Cable clearance behind: 3 inches (7.62 cm)
- Side clearance: 2 inches (5.08 cm)
- Indoor usage
- Do not install in direct sunlight
- Ambient Room Temperature: 18-30°C
- Transport and Storage Temperature: -20 to 50°C
- Humidity: 10-90% non-condensing
- Altitude: 0-2000 m
- Pollution degree 2 (IEC 664)
- Overvoltage Category II (IEC 664)
- Exterior: Lint-free 70% isopropyl alcohol in water
- Interior: Surface dependent – see User Guide
- Minimal user maintenance
- No operator replaceable parts
For more information on Accelerate Pheno™ system click here